CW-5000 Chiller View larger

CW-5000 Chiller

CW-5000 Chiller

New product

CW-5000 Industrial water Chiller with refrigiration compressor to keep your laser machine at a constant temperature. Water flow and temperature sensing with aduable alarm and warning light.

The Relay switch can also be connected directly to your laser machine to switch your laser power off if no water flow is detected.

More details

Warning: Last items in stock!

R15,584 tax incl.

R15,584 per unit

More info

CW-5000AG Industrial Water Chiller , 0.4HP, AC 1P 220V, 50Hz

for Single 80W/130W CO2 Laser Tube Cooling

NOTE:

800W cooling capacity, 30W DC pump,

 1 outlet and 1 inlet. Emitting rate higher than 60%. 

The water temperature is able to be adjusted.


(1931) CW-5000AG Water Chiller for Single 120W CO2 Laser Tube Cooling AC Advertising

Model

CW-5000AG

Power Supply

AC 1P 220V, 50Hz

Current

1.4 - 2.1A

Compressor Power

0.295KW

0.4HP

Refrigerating Capacity

2361Btu / h

0.692KW

595Kcal / h

Refrigerant

R – 134a

Refrigerant Charge

300g

Precision

±0.3℃

Tank Capacity

6L

Reducer

Capillary

Protection

Over current protection for compressor, flow alarm, over temperature alarm

Pump Power

0.03KW

Maximum Flow

10L / min

Maximum Pumping Lift

10M

Inlet and Outlet

External Dia.: 10mm brass connector

 


Alarm function:
E1
E2
E3
E4
E5
Over high room temperature
Over high water temperature
Over low water temperature
Room temperature sensor failure
Water temperature sensor failure

Remark:
When alarm occurs, the error code and the temperature will be alternately displayed.
In alarming state, the alarm sound could be suspended by pressing any button, but the alarm display remains 
until the alarm condition is eliminated.

 
Thermostat parameters list:
Order
Code
Project Setting
Range
Factory
Setting
Notes
1
F0
Temperature setting
F9 – F8
25
Constant temperature control effecting
2
F1
Temperature difference values
-15 - +5
-2
Intelligent control effecting
3
F2
Cooling hysteresis
0.1 – 3.0
0.8
 
4
F3
Way of control
0 - 1
1
1: intelligent
0: constant temperature
5
F4
Alarm for over high water temperature
1 - 20
10
 
6
F5
Alarm for over low water temperature
1 - 20
15
 
7
F6
Alarm for over high room temperature
40 - 50
45
 
8
F7
Password
00 - 99
8
 
9
F8
The allowed highest water temperature
F0 - 40
30
 
10
F9
The allowed lowest water temperature
1 – F0
20
 

 

 

Description:
This Water Chiller has been sold largely to Europe, South America, Asia and other markets.
• Cooling capacity is 800W.
• Specific disconnection alarm securing protection.
• With completed water flow and over high temperature alarm functions.
• You can choose different models according to local voltage and frequency.
• Have design patent Certificate, CE and RoHS Certificate..

• The hardware adopts new imported famous brand compressor and large capacity and high-lift S&A water pump;
• Most of the spare parts are S&A original;
• Temperature controller of this chiller has 2 models , constant temperature and intelligent temperature;
• Small thermolysis water cooler;
• It can control the water temperature, precision is ±0.3°C;
• Adopt intelligent controller;
• Multiple alarm function: compressor time-delay protection, compressor overcurrent protection, water flow alarm and over high / low temperature alarm;
• Equipped with alarm output port.
• Multiple power specifications; CE approval; RoHS approval.


• It is safe, protecting-environment, energy-saving and durable;
• Configured in a multitude of ways, works with stable performance and has a long lifespan;
• It can automatically switch to proper temperature on different occasions without change by yourself;
• Energy saving, long working life and simple operation;
• Provide stable working conditions for laser devices;
• Need not adjust the control parameters under normal circumstances, it will automatically adjust control parameters according to room temperature changes, to meet the cooling requirement;
• Low flow alarm protection function ensures the cooling water cycle working safely;
• Alarm output port can quickly protect sensitive components.

It is suitable for cooling the laser tube under 150W, and the temperature can be adjusted precisely.

• Economic cooling equipment, easy to install and operate, compact and easily movable;
• It can extend the using life of laser tube and ensure the engraving effect better;
• With setting and faults displaying function;
• With auto warning protection function.(Compressor delay protection, overcurrent protection, water flow alarm as well as high and low temperature alarm);
• High cost performance, low failure rate;
• Enclosed water tanks, water used for a long time;
• Conform to multinational supply specifications and with CE certificate.(1931) CW-5000AG Water Chiller for Single 120W CO2 Laser Tube Cooling AC details2

Temperature controller panel:


(1931) CW-5000AG Water Chiller for Single 120W CO2 Laser Tube Cooling AC details3

Under normal circumstance, the new intelligent temperature controller does not need to adjust the controlling parameters.
It will self-adjust controlling parameters according to room temperature, guaranteeing to meet cooling requirements for machines.

Alarm Function’s Description:
(1931) CW-5000AG Water Chiller for Single 120W CO2 Laser Tube Cooling AC function
Flow alarm and output ports:

In order to guarantee the equipment will not be damaged while cooling water circulation is out of control, CW-5000series chillers possesses an unique low flow alarm protection.

The cooling water circulation loop alarm causes and the work of the state table

 
Normal Flow
 Indicator
Flow Alarm
 Indicator
Buzzer
Output Ports
Hi, H2
Output Ports
H1, H3
Circulating pump works properly ON OFF NOT RING DISCONNECTION BREAKOVER
Blocked cooling water circulation loop OFF ON RING BREAKOVER DISCONNECTION
Alarm of water shortage OFF ON RING BREAKOVER DISCONNECTION
Faulted circulating pump OFF ON RING BREAKOVER DISCONNECTION
Power interruption / / / BREAKOVER DISCONNECTION


Note: 
The flow alarm is connected to the normally open relay and normally closed relay contacts, requiring operating current less than 5A, working voltage less than 300V.

(1931) CW-5000AG Water Chiller for Single 120W CO2 Laser Tube Cooling AC comparison

Our water cooling machine has S & A logo 
on the top of injection port
                                Fake cooler without the logo

Our water chiller has function of Intelligent temperature control   Fake cooler without this function

Our water chiller has S & A trademark in this label. This image is only to show the brand, specific parameters will vary depending on the model, please refer to the specifications table parameters prevail.           Fake cooler without this trademark                                                                                                                                                                                                                                                         

Our water chiller has S & A logo on the outfall                   Fake cooler without this logo

S & A trademark is printed on our water chiller.                                 Fake cooler without this trademark


Industrial cooling machine’s installation is very simple, the new machine for the first time using, you can install it as following steps.

A.Open the package to check if the machine is intact and all the necessary accessories are completed.

B.
Open the injection port to feed cooling water.
Observing the water level gauge and adding water slowly, be careful not to have the water overflowed! For the cooling of carbon steel equipment, the water should be added an appropriate amount of anti - corrosion agentia. Working in cold north area, it’s better to use noncorrosive antifreeze fluid.

C.
According to system conditions, please connect the water inlet and outlet pipe well.

D.
Plug in power, turn on the power switch. (Do not start up without water in the water tank!)
(1) Power switch turned on, the circulation pump of the chiller starts working. The first time of operating may cause more bubbles in the pipe leading to a flow alarming occasionally, but running for a few minutes later, it will go back to normal.
(2) After the first boot, you must immediately check whether the water pipe leaks.
(3) Power switched on, if the water temperature is below the set figure, it is normal that fans and other components of the machine do not work. The temperature controller will automatically control the working conditions of the compressor, magnetic valve, fans and other parts based on the set controlling parameters.
(4) As it takes a longer time to start the compressor and other components, according to different conditions, the time is range from seconds to minutes, so do not turn off the power and again on frequently.

E.Check the water level in the water tank.
The first startup of the new chiller empties the air in the water pipe, leading a slight water level decline, but in order to keep the water level in the green area, it’s allowed to add adequate water again. Please observe and record the current water level, and inspect it again after the chiller running for a period of time, if the water level drops obviously, please re-inspect the water pipeline leakage.

F.
Adjust parameters of temperature controller.
 CW-5000 series use an intelligent thermostat. Normally users do not need to adjust it. If it is really necessary, please refer to “Operating status and parameters adjustment.”
CW-5000AG Water Chiller for Single 120W CO2 Laser Tube Cooling usage
CW-5000AG Water Chiller for Single 120W CO2 Laser Tube Cooling usage

Maintenance
Cooling machine used in long term, you should open the machine and clean the dust in order to ensure good heat dissipation.
You can use non – corrosive antifreeze if you are in the northern cold regions.  

Cautions 

1. Please ensure that the power supply and electrical outlet are in good contact and the earth wire must be firmly grounded! Although the average operating current of the chiller is small, but the instantaneous operating current could be up to 6 ~ 10amps sometimes (The instantaneous operating current of models of AC110V power supply are possible to be up to 10 ~ 15amps).

2. Please make sure there is a stable and normal voltage for the working chiller! As the refrigeration compressor is more sensitive to the power supply and voltage, so the operating voltage of our standard product is of 200 ~ 250V (110V model is of 100 ~130V). If you do need a wider operating voltage range, customization is available for us.
3. To protect the pump, it’s strictly forbidden to run the chiller without having water in the storage water tank! The new machine is packed after draining whole water in the tank, so please make sure the tank has water inside before machine starting, otherwise it’s easily to have the pump damaged. When the water level is below the green (NORMAL) range of the water level gauge, the cooling capacity of our chiller will go down slightly. Hence please ensure the water level is within the green (NORMAL) range. To drain through circulating pump is strictly prohibited!

4. Please be sure that the air inlet and air outlet are in good ventilation! There must be at least 30cm from obstructions to the air outlet which is in the back of the cooler, and should leave at least 8cm between obstructions and the side air inlet.

5. The filter screen must be regularly cleaned! It’s essential to unpick and wash the dust gauze, or the serious blockage will cause breakdown to the chiller.

6. Please pay attention to the effect of the condensate water! With greater ambient humidity, when the water temperature is lower than the ambient temperature, the condensate water will generate on the surface of water circular pipes and the cooled components. If above circumstance appears, it is recommended to set a higher water temperature or keep pipes and cooled parts warm.


It is designed for cooling the one CO2 glass laser tube under 150W of high-speed spindle, electric spindle, CNC machine tools, jig mill, grinder, processing centers, laser marking machine, laser-beam welding machine, laser marking machine, laser cutting machine, etc. (Its emitting rate is higher than 60%.)